Product Details
Post date : 2011-03-12 02:44:05
reverse osmosis membrane-specific fungicides was fungicide-specific
system for microbial cells.
reverse osmosis membrane-specific fungicides
First, product performance
Reverse-specific fungicides was fungicide-specific system for
microbial cells have a very strong ability to penetrate, and
micro-organisms break down the cells have a destructive effect on
reverse osmosis equipment in bacteria, fungi, Micro-organisms such
as algae have a very strong inhibition and kill.
(1) non-oxidizing fungicides, rapid and effective sterilization;
(2) of the bacteria to form sticky mud of a certain role in
stripping;
(3) with all of the membrane can be compatible;
(4) applies to a wide range PH, biodegradable, and do not pollute
the environment.
Second, the characteristics of the product
a) reverse osmosis special fungicide is high bactericidal,
fungicidal fast, and strong inhibition.
b) reverse osmosis special fungicide is extended-spectrum
bactericidal: reverse osmosis water system to kill common bacteria,
fungi, algae micro-organisms, and so on.
c) Reverse Osmosis special fungicide has operational safety:
non-combustible, non-volatile.
Third, technical indicators
Item
Indicators
Appearance
Transparent liquid
PH Value(1%aqueous solution)
2.0-5.0
Density (20C)g/cm3
1.02
Actives%
3
Fourth, how to use
Reverse-specific fungicides use of the following 2:
1. Run through the process of accession to the metering pumps for
water, for the addition of 400ppm; about 2 weeks by adding 1 per 30
minutes. In this way uninterrupted water desalination production,
but the large amount of Pharmacy.
2. RO system to stop using chemical cleaning methods of
sterilization solution configuration, and the cycle of liquid
handling systems. If serious pollution should be on-site chemical
cleaning system, according to the following steps to deal with
sterilization system:
1) water tank to wash, reverse osmosis preparation of the special
fungicide, concentration of 400-800ppm;
2) regulation of cleaning fluid in the PH below 7 (citric acid, or
hydrochloric acid can be used with the aim of extending the
half-life of LSB881);
3) The cycle of 45 minutes.
Fifth, the use of Notes
Reverse-specific fungicides in use, if the water contains dissolved
hydrogen sulfide or iron or manganese ions (chlorine and hydrogen
peroxide) can not use this fungicide. Reverse-specific fungicides
corrosive, and to prevent skin, eye contact.
Six, packaging and storage
Reverse-specific fungicides is with plastic barrel, 25kg. Dark
storage at room temperature a year.
Product & Shipping Terms:
Port: TIANJIN
Notice : This informations are posted by a Free Member.
Bjsq recommend you to deal with Premium Members as they have been verified by our authentication and verification system. For more information on Premium Membership.